Sized for this cabin. These selections account for the standard glass front, timber construction and each heater manufacturer’s sizing rules. HIVE 15 is Leil’s recommendation for Single 2.4 and 2.6. Air L 15 covers both depths. CORE 11 is offered for Single 2.4. Harvia CLUB K15G is our Harvia choice for Single 2.6.
Use the centered heater position. Both depths have approximately 80½″ of interior height at the center. Install on the standard floor in the rear center bay and maintain the heater manual’s wall, bench and overhead clearances. Keep CORE and CLUB at the factory floor level, without a raised platform or added overhead trim.
Interior height and minimum room heights
| Cabin / heater |
Room height |
| Single 2.4 & 2.6 |
Approx. 80½″ at the center |
| HUUM CORE 11 |
80″ minimum |
| HUUM HIVE 12 / 15 |
77″ minimum |
| Saunum Air L 15 |
73″ minimum |
| Harvia CLUB K15G |
78″ minimum; 52″ clear above the heater rim |
Air L ventilation. Place the air outlet below the underside of the bench and leave its 20″ discharge zone clear. While the fan runs, keep adults at least 20″ and children at least 40″ from the outlet. Your installer must provide Saunum’s intake, exhaust and sensor layout during assembly.
CLUB installation. Use the centered rear bay. Keep 6″ between the heater and walls or benches, 2½″ to the wooden safety rail and 52″ above the heater rim. Keep the rail below the rim. The package uses Xenio controls with their power unit and three 44 lb boxes of Harvia stones. The metal stone grille does not replace the wooden safety rail. Provide 45 square inches each of intake and exhaust ventilation, and install the controls and power unit in a dry indoor location.
Electrical and stone loading. These packages use US 240 V, single-phase equipment. Have your electrician follow the exact heater and controller wiring diagrams. Load stones to the heater manual and retain any surplus.
Changing the cabin? These choices are for the standard glass-front layout. Send us your revised plan before adding glass, tile or changing the interior so we can size the equipment for that configuration.
Why these sizes? HIVE 18 exceeds the standard cabin’s sizing or clearance limits. Harvia Spirit 9, KIP 8, Saunum Air L 10 and Air Perfect 10 are too small once the required timber and glass allowances are included.
Cabin drawings · Leil assembly drawings · HIVE US manual · CORE US manual · Air L US manual · CLUB US manual